4 resultados para Estabilidade

em Universidade Federal de Uberlândia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sorghum (Sorghum bicolor (L.) Moench) is a good alternative to be used as silage, especially in places with water scarcity and high temperatures, due to their morphological and physiological characteristics. The appropriate management, as the ideal seeding time, interferes both productivity and the quality of silage. The work was conducted with the objective of evaluating the agronomic and bromatological performance of varieties and hybrids of silage sorghum and their phenotypic stability in two seasons, season and off-season, in the city of Uberlândia, Minas Gerais. The experiments were performed at Capim Branco Experimental Farm of Federal University of Uberlândia (UFU), located in the referred city. There were two sowing dates in the same experimental area, off-season (March to June 2014) and season (November 2014 to March 2015), and the varieties and hybrids were evaluated in both situations. The design was a randomized block with 25 treatments (hybrids and varieties of sorghum) and three replications. Agronomical and bromatological data were subjected to an analysis of variance; averages were grouped by Scott-Knott test at 5% of probability, through Genes computer program; and to estimate the stability, it was opted for Annicchiarico method. The flowering of cultivars, dry matter productivity, plant height, Acid Detergent Fiber (ADF), Neutral Detergent Fiber (NDF) and Crude Protein (CP) are affected by the environment and the variety. Regarding productivity and quality of the fiber, SF11 variety was superior, independent of the rated environment. In relation to the performance stability of dry matter, the varieties SF15, SF11, SF25, PROG 134 IPA, 1141572, 1141570 and 1141562 were highlighted. For the stability of the quality of fibers (FDA and FDN), the variety 1141562 stood out. The environment reduces the expression of characters “days of flowering”, “plant height” and “productivity of dry matter of hybrids”. From the 25 hybrids analyzed for productivity and stability of dry matter performance, seven were highlighted, regardless of the rated environment: Volumax commercial hybrid and experiments 12F39006, 12F39007, 12F37014, 12F39014, 12F38009 and 12F02006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CHAPTER II - This study evaluated the effects of two different types of acute aerobic exercise on the osmotic stability of human erythrocyte membrane and on different hematological and biochemical variables that are associated with this membrane property. The study population consisted of 20 healthy and active men. Participants performed single sessions of two types of exercise. The first session consisted of 60 min of moderate-intensity continuous exercise (MICE). The second session, executed a week later, consisted of high-intensity interval exercise (HIIE) until exhaustion. The osmotic stability of the erythrocyte membrane was represented by the inverse of the salt concentration (1/H50) at the midpoint of the sigmoidal curve of dependence between the absorbance of hemoglobin and the NaCl concentration. The values of 1/H50 changed from 2.29 ± 0.1 to 2.33 ± 0.09 after MICE and from 2.30 ± 0.08 to 2.23 ± 0.12 after HIIE. In MICE has occurred an increase in the mean corpuscular volume, probably due to in vivo lysis of older erythrocytes, with preservation of cells that were larger and more resistant to in vitro lysis. The study showed that a single bout of acute exercise affected the erythrocyte osmotic stability, which increased after MICE and decreased after HIIE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CHAPTER 1 - This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrillinggroup) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32). Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed. CHAPTER 2 - The objective of this preliminary histologic study was to determine whether the alteration of drilling protocols (oversized, intermediate, undersized drilling) present different biologic responses at early healing periods of 2 weeks in vivo in a beagle dog model. Ten beagle dogs were acquired and subjected to surgeries in the tibia 2 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.5 mm, 3.75 mm, and 4.0 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical significance was set to 95% level of confidence and the number of dogs was considered as the statistical unit for all comparisons. For the torque and BIC and BAFO, a general linear model was employed including instrumentation technique and time in vivo as independent. Overall, the insertion torque increased as a function of drilling diameter from 4.0 mm, to 3.75 mm, to 3.5 mm, with a significant difference in torque levels between all groups (p<0.001). Statistical assessment of BIC and BAFO showed significantly higher values for the 3.75 mm (recommended) drilling group was observed relative to the other two groups (p<0.001). Different drilling dimensions resulted in variations in insertion torque values (primary stability) and different pattern of healing and interfacial remodeling was observed for the different groups. CHAPTER 3 - The present study evaluated the effect of different drilling dimensions (undersized, regular, and oversized) in the insertion and removal torques of dental implants in a beagle dog model. Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical analysis was performed by paired t tests for repeated measures and by t tests assuming unequal variances (all at the 95% level of significance). Overall, the insertion torque and removal torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2 mm and 3.5 mm relative to the 3.8 mm groups (P < 0.03). Although insertion torque–removal torque paired observations was statis- tically maintained for the 3.5 mm and 3.8 mm groups, a significant decrease in removal torque values relative to insertion torque levels was observed for the 3.2 mm group. A different pattern of healing and interfacial remodeling was observed for the different groups. Different drilling dimensions resulted in variations in insertion torque values (primary stability) and stability maintenance over the first weeks of bone healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the creation of supersonic vehicles, during the Second World War, the engineers have given special attention to the interaction between the aerodynamic efforts and the structures of the aircrafts due to a highly destructive phenomenon called flutter in aeronautical panel. Flutter in aeronautical panels is a self-excited aeroelastic phenomenon, which can occurs during supersonic flights due to dynamic instability of inertia, elastic and aerodynamic forces of the system. In the flutter condition, when the critical aerodynamic pressure is reached, the vibration amplitudes of the panel become dynamically unstable and increase exponentially with time, affecting significantly the fatigue life of the existing aeronautical components. Thus, in this paper, the interest is to investigate the possibility of reducing the effects of the supersonic aeroelastic instability of rectangular plates by applying passive constrained viscoelastic layers. The rationale for such study is the fact that as the addition of viscoelastic materials provides decreased vibration amplitudes it becomes important to quantify the suppression of plate flutter coalescence modes that can be obtained. Moreover, despite the fact that much research on the suppression of panel flutter has been carried out by using passive, semi-active and active control techniques, very few of them are adapted to deal with the problem of estimating the flutter speeds of viscoelastic systems, since they must conveniently account for the frequency- and temperature-dependent behavior of the viscoelastic material. In this context, two different model of viscoelastic material are developed and applied to the model of sandwich plate by using finite elements. After the presentation of the theoretical foundations of the methodology, the description of a numerical study on the flutter analysis of a three-layer sandwich plate is addressed.